The TUVL-315 is the OEM replacement UV lamp for Fresh-Aire UV APCO-X and APCO-X Ultra in-duct air treatment systems. If your unit is flashing blue or showing a lamp replacement alert, this is the lamp you need. Using any other lamp voids the manufacturer warranty — only the TUVL-315 is approved for these systems.
UV lamps lose germicidal effectiveness gradually over time, even when they still emit visible light. Fresh-Aire UV rates this lamp for 3 years of effective germicidal output. Once that window passes, the UVC output drops sharply and the system is no longer doing its job — even if the light looks fine. Replace on schedule, not when it burns out.
Compatible Systems
- Fresh-Aire UV APCO-X Ultra (TUV-APCOX-U) — single lamp
- Fresh-Aire UV APCO-X Ultra Dual (TUV-APCOX-UD) — requires 2 lamps
- Fresh-Aire UV APCO-X (all single and dual configurations)
- Fresh-Aire UV Blue-Tube UV-X
Specifications
| Part Number | TUVL-315 |
| Lamp Life | 3 years (germicidal effectiveness) |
| Length | 14" (357mm) |
| Electrical | 425 mA, 17W |
| UVC Output | 5.7 UVC Watts |
| UV Intensity | 57 µW/cm² @ 1 meter |
| Wavelength | 254nm (germicidal UVC) |
| Ozone Output | None |
LED Status Indicator Reference (APCO-X Ultra)
- Flashing Blue — Replace UV lamp (lamp approaching end of rated life)
- Flashing Red — UV lamp expired
- Solid Red — UV lamp failure
How to Replace
Turn off power to the unit before servicing. Remove the cover using the thumb screws, disconnect the existing lamp from its connector, and pull it free from the quick nuts. Insert the new TUVL-315, reconnect the lamp cable (align the four pins), and secure with the quick nuts. Replace the cover. After reinstalling, use the timer set button on the power head to reset the 3-year lamp timer — hold for 5 seconds to enter timer mode, then press once to set a 1-year interval, twice for 2 years, or three times for 3 years. UV lamps contain small amounts of mercury — dispose of used lamps in accordance with local environmental regulations. See lamprecycle.org for disposal options.
Warranty
This is an OEM replacement part sold by Fresh-Aire UV. Use of non-OEM lamps voids the Fresh-Aire UV system warranty. Warranty on this lamp is provided by Fresh-Aire UV; all warranty claims and product support should be directed to the manufacturer.
Returns & Exchanges
We want every order to go smoothly, and if something is not right we want to make it right. At the same time, for the health and safety of everyone — our team, other customers, and the facilities these products are used in — we cannot resell opened or used filtration and air quality products. Our policy below is built around that reality. If you have any questions about a product before ordering, please reach out — we would rather help you get the right thing the first time than deal with a return after the fact.
Eligibility
Opened or used items are not eligible for return or refund under any circumstances. Products designated as Special Order, Clearance, Discontinued, or Final Sale are also not eligible for return or exchange. All other returns require items to be unused, in new condition, and in original packaging with all accessories and documentation included.
30-Day Return Policy
Unopened, unused items may be returned within 30 days of delivery, subject to a restocking fee of at least 25% of the purchase price. Original shipping costs are not refunded. Return shipping is the buyer's responsibility. A Return Material Authorization (RMA) number is required before shipping any return — contact us first at Help@HEPAFilterSales.com to receive return instructions. Returns sent without an RMA may be refused.
Refunds are processed within 10 business days of receiving and inspecting the returned item. You will be notified by email when your refund has been issued.
Exchanges — Standard Restocking Charge Waived
Exchanges for unopened, unused items are not subject to a restocking fee. Contact us at Help@HEPAFilterSales.com before returning any item to arrange an exchange and receive expert advice on the correct solution.
Order Cancellations
Contact us immediately if you need to cancel an order. Not all orders can be cancelled once placed — freight and special-order items in particular may ship before a cancellation can be processed.
Damaged or Incorrect Items
If your order arrives damaged, note the damage with the delivery carrier at time of delivery, photograph the damage, and email us within 48 hours of delivery at Help@HEPAFilterSales.com. We will arrange return shipping and send a replacement at no additional cost to you.
If you receive an incorrect item (compared to what was ordered), email us your order number and a description of the issue. We will arrange return shipping and send the correct item at no cost to you.
Defective Items
Suspected product defects and performance issues are warranty matters handled directly by the manufacturer — they are not eligible for return or return shipping reimbursement from HEPA Filter Sales, LLC. Contact us and we will provide manufacturer contact information to assist with a warranty claim.
For More Information, please take a moment to review our governing policies:
Returns & Refunds Policy
Shipping Policy
Purchase Options & Subscription Policy