Abatement Technologies HEPA-CARE HC800CD Ceiling-Mounted Air Filtration System

    Sale price $5,879.99 USD --1% Regular price $5,804.50 USD
    Regular price $5,879.99 USD
    Abatement Technologies HEPA-CARE HC800CD Ceiling-Mounted Air Filtration System
    Sale price $5,879.99 USD Regular price $5,804.50 USD
    Regular price $5,879.99 USD

    Product Details

    The HEPA-CARE® HC800CD is a dual-impeller, ceiling-mounted HEPA air purification system for patient isolation rooms, healthcare construction zones, and large fixed environments requiring controlled negative pressure, recirculation, or positive pressure airflow. It is registered as a Class II Medical Device under FDA 510(k) and independently tested and certified to UL and CSA safety standards by TÜV SÜD, an OSHA-accredited Nationally Recognized Testing Laboratory (NRTL).

    The HC800CD suspends above the ceiling in a standard 2 ft × 4 ft drop ceiling grid. Two EC motorized impellers deliver up to 850 CFM of HEPA-filtered airflow — capable of maintaining 12 or more air changes per hour in rooms up to approximately 3,000–3,500 cubic feet. The wall-mounted control panel (HC880CP) connects via CAT-5e and can be mounted in the room or remotely. The unit is hard-wired to the building electrical system — installation must be performed by qualified maintenance personnel and all wiring by a licensed electrician per local, NEC, and CEC codes.

    Important: The HC800CD is designed for indoor use only. It is not intrinsically safe for use in hazardous, combustible, flammable, or oxygen-deficient atmospheres. For general ventilating use only — do not use to exhaust hazardous or explosive materials.

    HC800CD vs. HC500CD — Which Unit Is Right for the Room?

    HC800CD HC500CD
    Ceiling Grid 2 ft × 4 ft 2 ft × 2 ft
    Impellers 2 EC motorized 1 EC motorized
    Peak Airflow 850 CFM 550 CFM (grille)
    Max Room Size (12 ACH) ~3,000–3,500 ft³ ~2,250–2,750 ft³
    HEPA Filter P/N HC1836-H14 HC1818-H14
    Net Weight 77 lbs 44 lbs

    Two-Stage Filtration

    Air enters through the louvered bottom intake grille and passes through two filter stages. The first stage is a 2" pleated MERV 8 particulate pre-filter (P/N: HC1802AM) that protects the HEPA filter from premature loading. The second stage is an individually tested and certified H14 HEPA filter (P/N: HC1836-H14) with a pharmaceutical-grade silicone-gel seal — certified to capture at least 99.995% of particles at the most penetrating particle size (MPPS). The gel seal creates a zero-bypass perimeter seal, forcing all air through the filter media. Both filters must be installed and the hinged access door secured before operating the unit.

    An optional VAPOR-LOCK® high-capacity activated carbon pre-filter (P/N: HC1802CF) is available separately in place of the standard pleated pre-filter for OVG (odors, vapors, gases) capture. The standard particulate filters do not remove odors, vapors, gases, or volatile organic compounds.

    Modes of Operation

    Negative Pressure Unit placed inside the containment area. Exhaust is ducted outside via rigid or flexible duct at the outlet. HEPA-filtered exhaust volume must exceed air entering the room by at least 10% or 100 CFM to maintain the pressure differential. Recommended for patient isolation per CDC/CSA requirements.
    Recirculation Filtered exhaust returns directly into the same room. Used to continuously reduce airborne contaminant concentrations without creating pressure differentials.
    Positive Pressure Unit placed outside the containment area. HEPA-filtered air is ducted into the protected space. Unit must be located outside the containment area when used in this mode.

    Technical Specifications

    Model HC800CD
    Regulatory Status FDA 510(k) Registered Class II Medical Device
    Safety Certification TÜV SÜD | UL | CSA | NRTL certified | UL 900
    Power Supply 120 VAC | 60 Hz | 15 A (hard-wired)
    Normal Operating Amps 6 A or less
    Circuit Breaker 5 A (on-unit)
    Airflow Range Up to 850 CFM (clean filters)
    Motor Speed Settings 5 (touchscreen)
    Motorized Impellers 2 EC motorized impellers
    HEPA Filter H14 | 99.995% @ MPPS | pharmaceutical-grade silicone-gel seal | P/N: HC1836-H14
    Pre-filter 2" pleated MERV 8 | P/N: HC1802AM
    Optional Pre-filter VAPOR-LOCK® activated carbon | P/N: HC1802CF
    Sound Level 35–59 dB(A) @ 5 ft
    Cabinet Powder-coated aluminum | riveted and sealed
    Dimensions (L × W × H) 46.875" × 22.875" × 16.25" (119.063 × 58.1 × 41.275 cm)
    Net Weight (with filters) 77 lbs (34.93 kg)
    Shipping Weight 90 lbs
    Ceiling Grid Compatibility Standard 2 ft × 4 ft drop ceiling grid
    Control Panel HC880CP | 3.25" touchscreen LCD | wall-mounted | CAT-5e connection
    HEPA Change Interval When loaded, at 1,500 hours of use, or every 2 years — whichever comes first
    Warranty 2 years — material and workmanship | filter service life not included
    Best Suited For Patient isolation | healthcare construction | critical environment protection

    Replacement Filters & Accessories

    HC1802AM 2" pleated MERV 8 pre-filter (standard)
    HC1802CF VAPOR-LOCK® 2" activated carbon pre-filter (optional — OVG capture)
    HC1836-H14 H14 HEPA filter | 99.995% | gel seal — HC800CD specific

    Use only Abatement Technologies OEM pre-filters, HEPA filters, and replacement parts. Substitute filters and parts void the warranty, jeopardize worker and environmental safety, and adversely affect engineered performance levels.

    Abatement Advantage Pricing

    The HC800CD is eligible for Abatement Advantage volume discount pricing. Contact us for pricing on multi-unit orders.

    Recommendations