The high-tech HEPA-CARE HC800FD Air Purification System from Abatement Technologies can be used to convert a patient room into a CDC-compliant negative pressure isolation room. The HC800FD floor model is equipped with an H14 Type HEPA filter tested and certified to capture at least 99.99% of microscopic particles 0.3 microns in size.
Please allow 8-12 weeks ARO.
High-performance motorized blowers produce peak rated airflow from 150 up-to 925cfm*, and can typically maintain 12 or more air changes per hour (ACH) in areas as large as 3,500-4,500 ft3*. The upright, slender-profile design with easy-rolling, swivel casters facilitates using the HC800FD in tight spaces.
When not used for negative pressure patient isolation, the versatile HC800FD can function as a recirculating HEPA air cleaner, reducing airborne pathogen counts in high-risk areas such as ER waiting rooms and treatment areas. Air laden with deadly, infectious airborne pathogens is pulled through two filter stages:
Remove Odors and Gases With a VAPOR-LOCK® Carbon Filter
Optional VAPOR-LOCK carbon pre-filters are available for the HC800FD or HC800FDUV, to remove airborne gas phase contaminants and odors from the air. These filters are used in place of the standard particulate pre-filter.
Clean and Sterilize the Air with Optional Germicidal UV Disinfection
The HC800FDUV includes four ultraviolet germicidal irradiation UVGI lamps that emit germicidal ultraviolet light to inhibit the growth of bacteria and viruses. These lamps irradiate the filtered air before it is exhausted to an external environment or recirculated within the facility. UVGI lamps must be factory installed at the time of order.
With thousands of units in service, the state-of-the-art HC800 series filtration systems create an unmatched record of reliable performance operating 24/7/365. The new HC800 models feature:
Long-Life HEPA Filter with Strong Aluminum Frame
Each pharmaceutical-grade HEPA filter from Abatement Technologies is individually tested and certified in accordance with the Institute of Environmental Sciences and Technology IEST-RP-CC001 to provide minimum filtration efficiency of 99.99% against a 0.3 micron challenge aerosol. The high-performance HEPA filter is mounted within a strong anodized aluminum frame that will not warp or support microbial growth.
Silicone-Gel Seal Protects Against Contaminated Air Bypass
A downward-facing flange imbeds into a silicone-gel seal creating a channel that forces air through the HEPA filter and protects against the risk of contaminated air bypassing the filter.
Hinged Door for Rapid Filter Replacement
Hinged, the front door secures with two Phillips machine screws and provides quick access to the HEPA filter and the 2” particulate pre-filter for replacement or maintenance.
Integrated digital touchscreen
High-visibility, color LCD touch screen controls. Intuitive, menu-driven screens are accessed after opening the Password Entry Screen:
Airflow*: Five airflow settings: up-to 150 - 925 cfm*
Air Changes Per Hour: up-to 12+ ACH @ 3,500-4,000 ft.3*
Net Weight with Filters: 83 pounds
Shipping Weight: 100 pounds
Dimensions (W x D x H): 21.5" W x 20.374"D x 47.5""H
Motorized Impeller: 2 each 225 mm EC motorized impellers
Power Supply Requirements: 120 volts AC, 60Hz, 15A
Energy Efficient: Operates at 125 watts or less
Electrical Safety: Certified as Class II Medical Devices under FDA 510K, and certified by an OSHA-accredited Nationally Recognized Testing Laboratory (NRTL), to comply with relevant UL and CSA safety standards
Control Panel: Intuitive, menu-driven, 3.25" LCD touchscreen display with password protection
Cabinet Material: Durable .050" white powder-coated aluminum for ease of cleaning & disinfection
Built-in Casters: Four easy-rolling casters with foot brakes
Easy to Replace Filters: Hinged filter access door secured with 2 Phillips machine screws