{"product_id":"mitsubishi-mhk2-kumo-touch™-wireless-redlink-remote-controller-kit","title":"Mitsubishi MHK2 kumo touch™ Wireless RedLINK Remote Controller Kit","description":"\u003cdiv class=\"hfs-product-description\"\u003e\n\u003c!-- LEAD --\u003e\n\u003cp\u003eThe MHK2 kumo touch™ is Mitsubishi Electric's wireless wall-mounted remote controller for mini split and multi-zone indoor units. It uses RedLINK™ 3.0 wireless technology to communicate with a receiver mounted at the indoor unit — no low-voltage thermostat wire run to the wall required. The backlit touchscreen provides full control of temperature, mode, fan speed, vane direction, and scheduling. Two AA batteries power the controller; no C-wire or 24V power supply needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The MHK2 uses RedLINK 3.0 and is not compatible with MHK1, MOS1, MCCH1, or other RedLINK 2.0 wireless devices. If you are replacing an MHK1, verify your indoor unit is on the compatibility list below before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ekumo cloud® Integration:\u003c\/strong\u003e The MHK2 can operate on the same indoor unit as the PAC-USWHS002-WF-2 Wireless Interface 2 (sold separately). Both devices connect to the indoor unit's CN105 port — the Wireless Interface 2 provides a second CN105 connector for this purpose. A Wireless Interface 2 is required if you want to control the unit remotely via the kumo cloud app in addition to using the MHK2 wall controller.\u003c\/p\u003e\n\u003c!-- WHAT'S IN THE BOX --\u003e\n\u003cp\u003e\u003cstrong\u003eKit Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMRCH2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWireless RedLINK 3.0 remote controller (wall-mounted thermostat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMIFH2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWireless RedLINK 3.0 receiver (mounts at or near indoor unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMRC2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection cable — connects MIFH2 receiver to CN105 on indoor unit control board | 39-23\/64\" (1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × AA alkaline (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- COMPATIBILITY --\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Indoor Units\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll CITY MULTI®\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll P-Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll M-Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf you are unsure whether your indoor unit is compatible, contact us with your model number before ordering.\u003c\/p\u003e\n\u003c!-- CONTROLLER SPECS --\u003e\n\u003cp\u003e\u003cstrong\u003eMRCH2 Remote Controller Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBacklit touchscreen | 12 or 24-hour clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFahrenheit and Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn\/Off | Cool \/ Heat \/ Dry \/ Fan modes | Fan speed | Vane direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSet Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooling: 50°–99°F | Heating: 40°–90°F | Auto: 50°–90°F (dual setpoints)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScheduling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo schedule | MO–SU (daily) | MO–FR \/ SA \/ SU (5-1-1) | MO–FR \/ SA–SU (5-2) | Each day individual | kumo cloud as schedule holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemporary or permanent schedule override\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLockout Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn | Off | Mode | Fan speed | Setpoint | Vane direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensing Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMHK2 | Indoor unit | RedLINK Wireless IAS (Honeywell RCHTSENSOR) | Average of MHK2 and IAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Sensing Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMHK2 | RedLINK Wireless IAS | Average of MHK2 and IAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFilter sign display | Error code diagnostics | Auto mode deadband adjustment | Temperature offset adjustment | Humidity offset adjustment | Indoor temp\/humidity hide option | Factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWireless\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedLINK™ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × AA alkaline batteries (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-5\/64\" × 4-5\/64\" × 1-1\/16\" (104 × 104 × 27 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°–120°F (0°–48.9°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5%–90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- RECEIVER SPECS --\u003e\n\u003cp\u003e\u003cstrong\u003eMIFH2 Wireless Receiver Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounts next to or near indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRC2 cable to CN105 connector on indoor unit control board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWireless\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedLINK™ 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-3\/32\" H × 1-3\/4\" W × 39\/64\" D (74.8 × 44.4 × 15.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°–165°F (-40°–73.9°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5%–95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- OPTIONAL ACCESSORIES --\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Accessories (Sold Separately)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePAC-USWHS002-WF-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWireless Interface 2 — required for kumo cloud app remote access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePAC-WHS01IE-E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN105 IT Extender\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHoneywell RCHTSENSOR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedLINK 3.0 Wireless Indoor Air Sensor (P\/N: C7189R2002) — not sold by Mitsubishi Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- OEM NOTE --\u003e\n\u003cp\u003eUse only genuine Mitsubishi Electric OEM accessories with the MHK2. Refer to the MHK2 installation manual for wiring diagrams and CN105 connection instructions.\u003c\/p\u003e\n\u003cp\u003eDownload the Install Manual \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2657\/5818\/files\/MHK2_Installation-Manual.pdf?v=1778680828\" title=\"MHK2 Install Manual\"\u003eHere\u003c\/a\u003e\u003cbr\u003eDownload the Operation Manual \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2657\/5818\/files\/mitsubishi_mhk2_operation_manual.pdf?v=1778680830\" title=\"MHK2 Operation Manual\"\u003eHere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":48169771434225,"sku":"MIT-MHK2","price":479.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2657\/5818\/files\/Mitsubishi_MHK2.jpg?v=1778679908","url":"https:\/\/hepafiltersales.com\/products\/mitsubishi-mhk2-kumo-touch%e2%84%a2-wireless-redlink-remote-controller-kit","provider":"HEPAFilterSales.com","version":"1.0","type":"link"}