{"product_id":"abatement-technologies-rpm-rt2-dual-room-pressure-monitor","title":"Abatement Technologies RPM-RT2 Dual Room Differential Pressure Monitor","description":"\u003cdiv class=\"hfs-product-description\"\u003e\n\n  \u003c!-- LEAD --\u003e\n  \u003cp\u003eThe RPM-RT2 is Abatement Technologies' dual-room wall-mounted differential pressure monitor. It simultaneously monitors and records the pressure relationships between three locations — two monitored rooms and a reference area — providing 24\/7 oversight of negative and positive pressure conditions in patient isolation rooms, protective environments, cleanrooms, hospital construction zones, and central sterilization\/sterile processing departments.\u003c\/p\u003e\n\n  \u003cp\u003eThe RPM-RT2 shares the same touchscreen interface, alarm system, logging, and network capabilities as the RPM-RT1, with the addition of a second pressure sensor input (ROOM B) and support for two RPM-RTSENSOR temperature\/humidity sensors. If you only need to monitor one room, see the \u003ca href=\"\/products\/abatement-technologies-rpm-rt1-room-pressure-monitor\"\u003eRPM-RT1\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003c!-- RPM-RT1 vs RPM-RT2 --\u003e\n  \u003cp\u003e\u003cstrong\u003eRPM-RT1 vs. RPM-RT2 — Which Monitor Do You Need?\u003c\/strong\u003e\u003c\/p\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003c\/td\u003e\n        \u003ctd\u003e\u003cstrong\u003eRPM-RT1\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e\u003cstrong\u003eRPM-RT2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003ePressure Inputs\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e1 (ROOM A)\u003c\/td\u003e\n        \u003ctd\u003e2 (ROOM A + ROOM B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eRooms Monitored\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e1\u003c\/td\u003e\n        \u003ctd\u003e2 simultaneously\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eTemp\/RH Sensors\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eUp to 2\u003c\/td\u003e\n        \u003ctd\u003eUp to 2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eKit P\/N\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eRPM-RT1K\u003c\/td\u003e\n        \u003ctd\u003eRPM-RT2K\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- FEATURES --\u003e\n  \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eThe RPM-RT2 monitors the pressure differential between each room and the adjacent reference area across a range of -0.10 in. water gauge (-25 Pa) to +0.10 in. water gauge (+25 Pa). Alarm thresholds are configurable from -0.04 to +0.04 in. water gauge (-10 to +10 Pa) at 0.001 in. WC (0.025 Pa) resolution. The color-coded touchscreen background — green, yellow, or red — provides instant visual status for both rooms from across the room. Audible alarms include delay and timed shutoff settings. Password protection is included and can be disabled.\u003c\/p\u003e\n\n  \u003cp\u003eData is logged to internal non-volatile memory (up to 12,000 events) and can be exported in CSV format via USB flash drive or accessed via BACnet or N2 network protocols for building management system integration. Calibrations are traceable to NIST standards.\u003c\/p\u003e\n\n  \u003cp\u003eOptional RPM-RTSENSOR temperature and relative humidity sensors can be added to either or both rooms. When sensors are connected, temperature and RH data is logged alongside pressure data and can trigger independent alarms when set limits are exceeded. Sensors and cables are not included with the base RPM-RT2 — see the kit configuration (RPM-RT2K) or order sensors and cables separately.\u003c\/p\u003e\n\n  \u003c!-- SPECS TABLE --\u003e\n  \u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRPM-RT2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (ROOM A and ROOM B)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.10 in. WC (-25 Pa) to +0.10 in. WC (+25 Pa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.04 in. WC (-10 Pa) to +0.04 in. WC (+10 Pa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 in. WC (0.025 Pa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eColor-coded touchscreen | green \/ yellow \/ red alarm status\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVisual and audible | audio delay and timed shutoff\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12,000 events in non-volatile internal memory\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Export\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive (CSV format)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBACnet and N2 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp\/RH Sensors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 2 × RPM-RTSENSOR (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNIST-traceable\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall-mounted | wall cutout template included\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePassword Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest Suited For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePatient isolation rooms | protective environments | cleanrooms | hospital construction | sterile processing departments\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- KIT CONFIG --\u003e\n  \u003cp\u003e\u003cstrong\u003eKit Configuration (RPM-RT2K)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eThe RPM-RT2K kit includes: 1 × RPM-RT2 pressure monitor | 2 × 25 ft clear tubing (HCPDPMTUBE) | 2 × RPM-RTSENSOR temperature\/RH sensors | 2 × 25 ft Ethernet cables (RPM-CABLE-025).\u003c\/p\u003e\n\n  \u003c!-- OPTIONAL ACCESSORIES --\u003e\n  \u003cp\u003e\u003cstrong\u003eOptional Accessories (Sold Separately)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM-RTSENSOR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote temperature and relative humidity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM-CABLE-025\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ft Ethernet cable — required to connect each RPM-RTSENSOR\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cp\u003eUse only Abatement Technologies OEM sensors and cables with the RPM-RT series monitors.\u003c\/p\u003e\n\n  \u003c!-- ABATEMENT ADVANTAGE --\u003e\n  \u003cp\u003e\u003cstrong\u003eAbatement Advantage Pricing\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eThe RPM-RT2 is eligible for Abatement Advantage volume discount pricing. Contact us for pricing on multi-unit orders.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Abatement Technologies Commercial","offers":[{"title":"Default Title","offer_id":48312773738737,"sku":"ABA-RPMRT2","price":1617.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2657\/5818\/files\/Abatementrpm-rt1.jpg?v=1773252779","url":"https:\/\/hepafiltersales.com\/products\/abatement-technologies-rpm-rt2-dual-room-pressure-monitor","provider":"HEPAFilterSales.com","version":"1.0","type":"link"}